Clear bevel cedar pre stained bleaching oil tx stk bevel cedar pre stained mahogany flame pa both faces are saw textured resulting in a perfect surface to soak in your stain or prime finish.
Installing bevel lap siding.
The average exposure distance is usually determined by the distance from the underside of the window sill to the top of the drip cap see figure a.
Fasten a cedar starter strip.
For horizontal applications start with the bottom course and work up with the channels pointing upwards.
At the bottom install a starter strip supplied by the manufacturer or install a 1 2.
The recommended exposure distances exposure distance is the amount of siding left exposed to the weather are 4 inches for 6 inch siding 8 inches for 10 inch siding and so on as shown in figure 3.
Do not nail through overlaps.
Install corner trim on all corners typically 1 by 4 inch boards nailed vertically with the wide face of a board.
Bevel lap siding should be installed with the lower thicker bevel butt edge overlapping the thin edge which results in an attractive shadow line.
Take care not to nail through the overlap of two pieces.
Place nail just above the overlap.
Installation of bevel siding.
For siding up to 6 inches wide use one nail one inch up from the lap.
For example you install fiber cement lap siding in much the same way as wood siding but most manufacturers advise you to leave 1 8 inch gaps at the ends of the boards to allow for expansion and then caulk the gaps.
Always follow the manufacturer s directions.
At an outside corner use a 1 3 and a 1 4 or a 1 2 and a 1 3.
The side with the narrower piece will look nearly as wide as the other because of the thickness of the other piece install all trim pieces around windows and doors.
The minimum lap for bevel siding should not be less than 1 inch.
Do not reduce the siding overlap recommendations given in the installation sections of this publication.
In those areas where an air space between siding and sheathing is desired nail siding to furring strips table 4.
Lap clapboard or beveled siding should lap no less than 1 inch and preferably 2 inches.
Allow a 1 8 inch expansion gap between pieces if the siding is air or kiln dried.
Wrap the house with a polyethylene or similar moisture barrier stapled to the wooden wall sheathing with a.
Horizontal siding installation siding should be nailed into studs at maximum 24 in centers when applied over wood based solid sheathing and 16 in.
Most lap siding is beveled meaning that the bottom edge is thicker than the top.
Lap siding can be installed horizontally or vertically.
On center when bevel sidings 11 16 or thinner are applied without sheathing.